A platelet count is a diagnostic test that determines the number of platelets in the patient's blood. Platelets, which are also called thrombocytes, are small disk-shaped blood cells produced in the bone marrow and involved in the process of blood clotting. There are normally between 150,000-450,000 platelets in each microliter of blood. Low platelet counts or abnormally shaped platelets are associated with bleeding disorders. High platelet counts sometimes indicate disorders of the bone marrow.
The primary functions of a platelet count are to assist in the diagnosis of bleeding disorders and to monitor patients who are being treated for any disease involving bone marrow failure. Patients who have leukemia, polycythemia vera, or aplastic anemia are given periodic platelet count tests to monitor their health.
Platelet counts use a freshly-collected blood specimen to which a chemical called EDTA has been added to prevent clotting before the test begins. About 5 mL of blood are drawn from a vein in the patient's inner elbow region. Blood drawn from a vein helps to produce a more accurate count than blood drawn from a fingertip. Collection of the sample takes only a few minutes.
After collection, the mean platelet volume of EDTA-blood will increase over time. This increase is caused by a change in the shape of the platelets after removal from the body. The changing volume is relatively stable for a period of one to three hours after collection. This period is the best time to count the sample when using electronic instruments, because the platelets will be within a standard size range.
Platelets can be observed in a direct blood smear for approximate quantity and shape. A direct smear is made by placing a drop of blood onto a microscope slide and spreading it into a thin layer. After staining to make the various blood cells easier to see and distinguish, a laboratory technician views the smear through a light microscope. Accurate assessment of the number of platelets requires other methods of counting. There are three methods used to count platelets; hemacytometer, voltage-pulse counting, and electro-optical counting.
HEMACYTOMETER COUNTING. The microscopic method uses a phase contrast microscope to view blood on a hemacytometer slide. A sample of the diluted blood mixture is placed in a hemacytometer, which is an instrument with a grid etched into its surface to guide the counting. For a proper count, the platelets should be evenly distributed in the hemacytometer. Counts made from samples with platelet clumping are considered unreliable. Clumping can be caused by several factors, such as clotting before addition of the anticoagulant and allowing the blood to remain in contact with a capillary blood vessel during collection. Errors in platelet counting are more common when blood is collected from capillaries than from veins.
ELECTRONIC COUNTING. Electronic counting of platelets is the most common method. There are two types of electronic counting, voltage-pulse and electrooptical
|
|
Author Info: John T. Lohr PhD, The Gale Group Inc., Gale, Detroit, Gale Encyclopedia of Medicine, 2002 |